GCE Medical products now found on gce-medical.com EXPLORE NOW close
Domovská stránka » CELTIC AML2 - DIRECT REGULATORS (SECOND STAGE REGULATOR)

CELTIC AML2 - DIRECT REGULATORS (SECOND STAGE REGULATOR)

The CELTIC range can be used for all common non-corrosive industrial gas. As for regulation, these products are very accurate.

APPLICATION

  • Second stage regulation to supply furnaces
  • Inertness (cisterns, pipes)
  • Pressure limiting device (AML2 with RD05 = "S")

PRODUCT ADVANTAGES

  • Watertightness in case of bad weather
  • All components comfortably accessible
  • Easy and fast dismantling
  • Simple and heavy-duty
  • Low closing pressure

CELTIC AML2-N

Art. Nr.  
Connection Gas

Max.inlet pressure
bar (psi)

Outlet
pressure
bar (psi)
Flow air Nm3/h
Flow propane kg/h
 I130621 G1"1/2"F N, M, P 8 (120) 0,1-0,8 (2-12)  70-190  100-290


CELTIC AML2-S (AML1 with RD05)

Art. Nr.  
Connection Gas

Max.inlet pressure
bar (psi)

Outlet
pressure
bar (psi)
Flow air Nm3/h
Flow propane kg/h
 I130623 G1"1/2"F N, M, P 8 (120) 0,3-0,8 (4-12)  70-190  100-290


SPARE PARTS

Maintenance kit for models with spring used with non-corrosive gas.

Art. Nr.
Model Contents
I291282 CELTIC AML2-N 1 diaphragm, 1 diaphragm washer (for AML2), 1 complete reagulating valve, 3 washers (plug, valve), 1 blind nut
I291264

Previous model of CELTIC AML2

1 diaphragm, 1 diaphragm washer (for AML2), 1 complete reagulating valve, 3 washers (plug, valve), 1 blind nut


ACCESSORIES

Outlet security kit for N-models not having outlet security device, GCE propose a security kit.

Art. Nr.
Model Outlet pressure Name
I291303 CELTIC AML2-N 0,3 to 0,8 bar Kit RD05 - C AML

The installation of the security device has to be done in our workshop.

TECHNICAL DATA

Max. inlet pressure: 8 bar
Material: Aluminium alloy body
Connection: Threaded inlet and outlet G 1“1/2"F (40x49)
Operating temperature range: from -20 to + 60°C

 

Technické listy Top

Technické listy ke stažení

Technické výkresy Top

Technické výkresy ke stažení